SN-LC1100
Scienovo
1 Years
OEM /ODM Service
Availability: | |
---|---|
Quantity: | |
Product Description |
Characteristics
Simple operation and convenient use.
Optimize the control protocol to make the communication between the workstation and the unit instrument module more smooth; Stable real-time feedback of the status and parameters of each unit module.
SN-LC1100 HPLC system is a cost-effective product, launched into the market in 2016. The use of core competencies of our experience ensures superior data quality, excellent stability, and long-term performance of the 1100 HPLC system. It is suitable for use in the production or manufacture which needs strict cost control.
Features
Simple to use.
Flexibility in data display
Real-time and fast determination of peak area
Easy review the entire system
Real-time operating status and indicator feedback of instrument units
Easy comparison of multiple chromatograms
Customizable reports
Supporting tools for GLP / 21 CFR Part 11- Audit trail of the whole system and chromatograms
User accounts-selectable rights, unique user profiles, allow creating a unique password to protect profiles of each user.
Specification |
P1100 High-Pressure Constant Flow Pump | 1) Double plunger reciprocating pump |
2) Flow Range: 0.001mL/min-10.000mL/min; Setting Step Size: 0.001mL/min | |
3) Flow Accuracy: ≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) | |
4) Flow stability: RSD≤0.1% (1.00ml/min, H2O, R.T.,8.5MPa) | |
5) Maximum Pressure: 42MPa | |
6) Psi, Mpa, bar (Optional Display of Pressure Unit) | |
7) Flow Accuracy Calibration | |
8) Power: AC 220V±10%, 50Hz | |
9) External Dimension (Length x Width x High): 420mm×260mm×160mm | |
D1100 UV/VIS Detector | 1)Wavelength Range:190-700nm |
2)Baseline Noise: ≤±1×10-5AU | |
3)Baseline Drift: ≤2.0×10-4AU/h | |
4)minimum Detectable Concentration: 4.0×10-9g/mL (Naphthalene in Methanol Solution) | |
5)Detector Cell: Optical Path--10mm, Volume--10μL | |
6)Light Source: Deuterium Lamp | |
7)Power: AC 220V±10%, 50Hz | |
8)External Dimension | |
(Length x Width x High): 420mm×260mm×160mm | |
01100 Column Oven: | Temperature range: Ambient + 5 °C~99 °C |
Accuracy:± 0.1 °C | |
Precision:M 0.1 °C | |
Power:AC220 V ±10%,50 Hz, 150 W | |
Dimensions/Weight:120*65 *500 mm (L* W* H*) /8.5 kg |
Product Description |
Characteristics
Simple operation and convenient use.
Optimize the control protocol to make the communication between the workstation and the unit instrument module more smooth; Stable real-time feedback of the status and parameters of each unit module.
SN-LC1100 HPLC system is a cost-effective product, launched into the market in 2016. The use of core competencies of our experience ensures superior data quality, excellent stability, and long-term performance of the 1100 HPLC system. It is suitable for use in the production or manufacture which needs strict cost control.
Features
Simple to use.
Flexibility in data display
Real-time and fast determination of peak area
Easy review the entire system
Real-time operating status and indicator feedback of instrument units
Easy comparison of multiple chromatograms
Customizable reports
Supporting tools for GLP / 21 CFR Part 11- Audit trail of the whole system and chromatograms
User accounts-selectable rights, unique user profiles, allow creating a unique password to protect profiles of each user.
Specification |
P1100 High-Pressure Constant Flow Pump | 1) Double plunger reciprocating pump |
2) Flow Range: 0.001mL/min-10.000mL/min; Setting Step Size: 0.001mL/min | |
3) Flow Accuracy: ≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) | |
4) Flow stability: RSD≤0.1% (1.00ml/min, H2O, R.T.,8.5MPa) | |
5) Maximum Pressure: 42MPa | |
6) Psi, Mpa, bar (Optional Display of Pressure Unit) | |
7) Flow Accuracy Calibration | |
8) Power: AC 220V±10%, 50Hz | |
9) External Dimension (Length x Width x High): 420mm×260mm×160mm | |
D1100 UV/VIS Detector | 1)Wavelength Range:190-700nm |
2)Baseline Noise: ≤±1×10-5AU | |
3)Baseline Drift: ≤2.0×10-4AU/h | |
4)minimum Detectable Concentration: 4.0×10-9g/mL (Naphthalene in Methanol Solution) | |
5)Detector Cell: Optical Path--10mm, Volume--10μL | |
6)Light Source: Deuterium Lamp | |
7)Power: AC 220V±10%, 50Hz | |
8)External Dimension | |
(Length x Width x High): 420mm×260mm×160mm | |
01100 Column Oven: | Temperature range: Ambient + 5 °C~99 °C |
Accuracy:± 0.1 °C | |
Precision:M 0.1 °C | |
Power:AC220 V ±10%,50 Hz, 150 W | |
Dimensions/Weight:120*65 *500 mm (L* W* H*) /8.5 kg |
Specification
Product Model | SN-LC1100 HPLC System |
Produt Name | HPLC System |
P1100 High-Pressure Constant Flow Pump | 1) Double plunger reciprocating pump |
2) Flow Range: 0.001mL/min-10.000mL/min; Setting Step Size: 0.001mL/min | |
3) Flow Accuracy:≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) | |
4) Flow stability: RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) | |
5) Maximum Pressure: 42MPa | |
6) Psi, Mpa, bar (Optional Display of Pressure Unit) | |
7) Flow Accuracy Calibration | |
8) Power: AC 220V±10%, 50Hz | |
9) External Dimension (Length x Width x High): 420mm×260mm×160mm | |
D1100 UV/VIS Detector | 1)Wavelength Range:190-700nm |
2)Baseline Noise: ≤±1×10-5AU | |
3)Baseline Drift: ≤2.0×10-4AU/h | |
4)minimum Detectable Concentration: 4.0×10-9g/mL (Naphthalene in Methanol Solution) | |
5)Detector Cell: Optical Path--10mm, Volume--10μL | |
6)Light Source: Deuterium Lamp | |
7)Power: AC 220V±10%, 50Hz | |
8)External Dimension | |
(Length x Width x High): 420mm×260mm×160mm | |
01100 Column Oven: | Temperature range: Ambient + 5 °C~99 °C |
Accuracy:± 0.1 °C | |
Precision:M 0.1 °C | |
Power:AC220 V ±10%,50 Hz, 150 W | |
Dimensions/Weight:120*65 *500 mm (L* W* H*) /8.5 kg |
Specification
Product Model | SN-LC1100 HPLC System |
Produt Name | HPLC System |
P1100 High-Pressure Constant Flow Pump | 1) Double plunger reciprocating pump |
2) Flow Range: 0.001mL/min-10.000mL/min; Setting Step Size: 0.001mL/min | |
3) Flow Accuracy:≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) | |
4) Flow stability: RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) | |
5) Maximum Pressure: 42MPa | |
6) Psi, Mpa, bar (Optional Display of Pressure Unit) | |
7) Flow Accuracy Calibration | |
8) Power: AC 220V±10%, 50Hz | |
9) External Dimension (Length x Width x High): 420mm×260mm×160mm | |
D1100 UV/VIS Detector | 1)Wavelength Range:190-700nm |
2)Baseline Noise: ≤±1×10-5AU | |
3)Baseline Drift: ≤2.0×10-4AU/h | |
4)minimum Detectable Concentration: 4.0×10-9g/mL (Naphthalene in Methanol Solution) | |
5)Detector Cell: Optical Path--10mm, Volume--10μL | |
6)Light Source: Deuterium Lamp | |
7)Power: AC 220V±10%, 50Hz | |
8)External Dimension | |
(Length x Width x High): 420mm×260mm×160mm | |
01100 Column Oven: | Temperature range: Ambient + 5 °C~99 °C |
Accuracy:± 0.1 °C | |
Precision:M 0.1 °C | |
Power:AC220 V ±10%,50 Hz, 150 W | |
Dimensions/Weight:120*65 *500 mm (L* W* H*) /8.5 kg |
Scienovo is a professional manufacture and supplier of scientific instruments in China, which is certified by ISO9001, ISO14001 and Intellectual Property Management System.
No.10 Building, Pujiang Village , No.1188, Lianhang Road, Minhang District, Shanghai , China.
+86-15901999577