Scienovo SN-GC1290
Scienovo
EPC 7 inch touch screen display Gas Chromatography
Ambient temperature +7℃ ~ 420℃ (in 1℃ increment)
± 0.02℃
FID/TCD/FPD/ ECD/NPD
1 Years
OEM /ODM Service
Availability: | |
---|---|
Quantity: | |
Product Description |
Features
Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by “control system”)
Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
Column oven supports quick heat-up and rapid cool-down with automated back-door opening.
Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Electronic pneumatics control system
Flow rate: 200ml/min (N2), 1000ml/min (He) Flow rate accuracy: ±5%
Flow rate repeatability: ±0.35% Split ratio: 0-5000(He), 0-1000(N2) Inlet
temperature: 0-420℃
Gas chromatography and accessories
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/TCD/FPD/ ECD/NPD
Advanced Microcomputer Control System
Superior performance with advanced, microcomputer-based temperature control system
High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference
Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
Intuitive display of timing program, detector status, measurement range, current setting, etc
Specification |
Product Model | SN-GC1290 | ||
Product Name | EPC 7 inch touch screen display Gas Chromatography | ||
Sample Introduction System | Sample Injector And Evaporation Chamber | ||
Column Oven | Temperature range | Ambient temperature +7℃ ~ 420℃ | |
Temperature accuracy | ± 0.02℃ | ||
Cooling time | 350℃~100℃《3min, | ||
Programmed temperature setting | 0.1℃~80℃/min (in 1℃ increment) | ||
Program ramps | 20 ramps in total (99 ramps available with control workstation) | ||
Size (L*W*H) | 284*280*241mm (inside) | 340*345*281mm (outside) | |
FID Flame Ionization Detector | Detection limit | ≤8×10-12g/s (n-hexadecane) | |
Best test result | |||
Drift | ≤1.5×10-13A/h | ||
Noise | ≤1.5×10-13A/h | ||
Linearity range | ≥106 | ||
TCD Thermal Conductivity Detector | Sensitivity | ≥10000mv • ml / mg (n-hexadecane) | |
Baseline noise | ≤20uv | ||
Drift | 《100uv / 30min (after the instrument is stable for 2 hours) (after the instrument is stable for 2 hours) | ||
Linearity range | ≥104 | ||
FPD Flame Photometric Detector | Detection limit | ≤8×10‐13g/s(P) ; ≤8×10‐11g/s(S) | |
Drift | ≤2×10‐11A/30min | ||
Baseline noise | ≤5×10‐12A | ||
NPD Nitrogen-Phosphorus Detector | Detection limit | 《5×10-12g/s(N) (Azobenzene) 《5×10-13g/s(P) (Malathion) | |
ECD Electron Capture Detector | Baseline drift | ≤ 100 μV/30min | |
Baseline noise | ≤ 40μV | ||
Detection limit | ≤3×10-14g/ml (γ-666) |
Product Description |
Features
Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by “control system”)
Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
Column oven supports quick heat-up and rapid cool-down with automated back-door opening.
Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Electronic pneumatics control system
Flow rate: 200ml/min (N2), 1000ml/min (He) Flow rate accuracy: ±5%
Flow rate repeatability: ±0.35% Split ratio: 0-5000(He), 0-1000(N2) Inlet
temperature: 0-420℃
Gas chromatography and accessories
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/TCD/FPD/ ECD/NPD
Advanced Microcomputer Control System
Superior performance with advanced, microcomputer-based temperature control system
High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference
Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
Intuitive display of timing program, detector status, measurement range, current setting, etc
Specification |
Product Model | SN-GC1290 | ||
Product Name | EPC 7 inch touch screen display Gas Chromatography | ||
Sample Introduction System | Sample Injector And Evaporation Chamber | ||
Column Oven | Temperature range | Ambient temperature +7℃ ~ 420℃ | |
Temperature accuracy | ± 0.02℃ | ||
Cooling time | 350℃~100℃《3min, | ||
Programmed temperature setting | 0.1℃~80℃/min (in 1℃ increment) | ||
Program ramps | 20 ramps in total (99 ramps available with control workstation) | ||
Size (L*W*H) | 284*280*241mm (inside) | 340*345*281mm (outside) | |
FID Flame Ionization Detector | Detection limit | ≤8×10-12g/s (n-hexadecane) | |
Best test result | |||
Drift | ≤1.5×10-13A/h | ||
Noise | ≤1.5×10-13A/h | ||
Linearity range | ≥106 | ||
TCD Thermal Conductivity Detector | Sensitivity | ≥10000mv • ml / mg (n-hexadecane) | |
Baseline noise | ≤20uv | ||
Drift | 《100uv / 30min (after the instrument is stable for 2 hours) (after the instrument is stable for 2 hours) | ||
Linearity range | ≥104 | ||
FPD Flame Photometric Detector | Detection limit | ≤8×10‐13g/s(P) ; ≤8×10‐11g/s(S) | |
Drift | ≤2×10‐11A/30min | ||
Baseline noise | ≤5×10‐12A | ||
NPD Nitrogen-Phosphorus Detector | Detection limit | 《5×10-12g/s(N) (Azobenzene) 《5×10-13g/s(P) (Malathion) | |
ECD Electron Capture Detector | Baseline drift | ≤ 100 μV/30min | |
Baseline noise | ≤ 40μV | ||
Detection limit | ≤3×10-14g/ml (γ-666) |