SN-LC3100
Scienovo
1 Years
OEM /ODM Service
Availability: | |
---|---|
Quantity: | |
Product Description |
Features
Classic short strokeand multi-stage flow correction ensuring pump performance.
Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning.
Self-developed PID control measure bringing true the accuracy of column oven temperature to 0.1℃
The S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.
Application of optoelectronic isolation and EMI protection ensuring stable communication
All-round upgraded workstation that is operator-friendly and promotes customer experience.
Specification |
Item | Specification | |
LU3100 Quaternary Low-Pressure Unit | Flow Range | 0.001mL/min-10.000mL/min |
(Step 0.001mL/min) | ||
Precision | ≤±0.2% | |
Accuracy | RSD≤0.075% | |
Max Pressure | 45.0MPa | |
Power | AC220V±10%, 50Hz | |
Consumption | 80W | |
Dimensions | 420mm x 300mm x 175mm | |
D3110 Diode Array Detector | Linear range | 2.0AU |
Wavelength Range | 190nm-800nm(512 Diodes) | |
Wavelength Accracy | ≤±1.0nm | |
Spectral resolution | 1.2nm | |
Baseline Noise | ≤1.0x10-5AU | |
Baseline Drift | ≤2.0x10-4AU/h | |
Light Source | Deuterium lamp and Tungsten lamp | |
Power | AC220V±10%, 50Hz | |
Consumption | 100W | |
Dimensions | 500mm x 300mm x 175mm | |
UV3100 UV/VIS Detector | Linear range | 1.8AU |
Wavelength Range | 190nm-700nm | |
Wavelength Accracy | ≤±1.0nm | |
Wavelength Precsion | ≤0.1nm | |
Optical Bandwidth | 8nm | |
Baseline Noise | ≤±0.5x10-5AU | |
Baseline Drift | ≤1.0x10-4AU/h | |
Flow Cell | Optical path length 10mm | |
Light Source | Deuterium lamp | |
Power | AC220V±10%, 50Hz | |
Consumption | 100W | |
Dimensions | 420mm x 300mm x 175mm | |
O3100 Column Oven | Temperature Range | Ambient plus+5℃~80℃ |
Accuracy | ±0.3℃ | |
Temperature Precision | ≤±0.1℃ | |
Power | AC220V±10%, 50Hz | |
Consumption | 130W | |
Dimensions | 420mm x 300mm x 120mm | |
S3100 Auto-Sampler | Precision | RSD<0.3%(Full-loop) |
Sample Residual | <0.01% | |
Linear | R2>0.999 | |
Max Number of sample | 120 | |
Inject volume | 0-100μL(standard) | |
Inject Step | 0.1μL | |
Sample Loop | 100μL | |
Syringe volume | 500μL | |
Max Pressure | 35MPa | |
Power | AC220V±10%, 50Hz | |
Consumption | 30W | |
Dimensions | 540mm x 400mm x 300mm |
Product Description |
Features
Classic short strokeand multi-stage flow correction ensuring pump performance.
Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning.
Self-developed PID control measure bringing true the accuracy of column oven temperature to 0.1℃
The S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.
Application of optoelectronic isolation and EMI protection ensuring stable communication
All-round upgraded workstation that is operator-friendly and promotes customer experience.
Specification |
Item | Specification | |
LU3100 Quaternary Low-Pressure Unit | Flow Range | 0.001mL/min-10.000mL/min |
(Step 0.001mL/min) | ||
Precision | ≤±0.2% | |
Accuracy | RSD≤0.075% | |
Max Pressure | 45.0MPa | |
Power | AC220V±10%, 50Hz | |
Consumption | 80W | |
Dimensions | 420mm x 300mm x 175mm | |
D3110 Diode Array Detector | Linear range | 2.0AU |
Wavelength Range | 190nm-800nm(512 Diodes) | |
Wavelength Accracy | ≤±1.0nm | |
Spectral resolution | 1.2nm | |
Baseline Noise | ≤1.0x10-5AU | |
Baseline Drift | ≤2.0x10-4AU/h | |
Light Source | Deuterium lamp and Tungsten lamp | |
Power | AC220V±10%, 50Hz | |
Consumption | 100W | |
Dimensions | 500mm x 300mm x 175mm | |
UV3100 UV/VIS Detector | Linear range | 1.8AU |
Wavelength Range | 190nm-700nm | |
Wavelength Accracy | ≤±1.0nm | |
Wavelength Precsion | ≤0.1nm | |
Optical Bandwidth | 8nm | |
Baseline Noise | ≤±0.5x10-5AU | |
Baseline Drift | ≤1.0x10-4AU/h | |
Flow Cell | Optical path length 10mm | |
Light Source | Deuterium lamp | |
Power | AC220V±10%, 50Hz | |
Consumption | 100W | |
Dimensions | 420mm x 300mm x 175mm | |
O3100 Column Oven | Temperature Range | Ambient plus+5℃~80℃ |
Accuracy | ±0.3℃ | |
Temperature Precision | ≤±0.1℃ | |
Power | AC220V±10%, 50Hz | |
Consumption | 130W | |
Dimensions | 420mm x 300mm x 120mm | |
S3100 Auto-Sampler | Precision | RSD<0.3%(Full-loop) |
Sample Residual | <0.01% | |
Linear | R2>0.999 | |
Max Number of sample | 120 | |
Inject volume | 0-100μL(standard) | |
Inject Step | 0.1μL | |
Sample Loop | 100μL | |
Syringe volume | 500μL | |
Max Pressure | 35MPa | |
Power | AC220V±10%, 50Hz | |
Consumption | 30W | |
Dimensions | 540mm x 400mm x 300mm |
Scienovo is a professional manufacture and supplier of scientific instruments in China, which is certified by ISO9001, ISO14001 and Intellectual Property Management System.
No.10 Building, Pujiang Village , No.1188, Lianhang Road, Minhang District, Shanghai , China.
+86-15901999577