SN-CIC-D120 Ion Chromatograph

Maximum Pressure:   35MPa
Flow Range:  0.001~9.999mL/min
  • SN-CIC-D120

  • Scienovo

  • High-Pressure And Low-Pulse Double Plunger Tandem Advection Pump

  • 1 Years

  • OEM /ODM Service

Availability:
Quantity:


Product Description


Features

Temperature-control bipolar conductivity detector(CN 202033335U)

Greater detection range, better precise analysis

Built-in circulating 3D constant temperature technology ( CN 204259917U)

Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data

The world's leading full-range series of ion chromatographic columns(CN 105126936A、CN 104788603A)

High efficiency, large capacity of the columns for detecting ions of varied compositions.

Self-Regenerating Electrolytic Micro-membrane Suppressor ( CN 102735792A)

High pressure resistance, small dead volume, highly responsive to signals

Able to detect anions and cations at the ppb level.

Work across a variety of detectors, to expand the scope of applications of ion chromatography.


Specification


Chromatographic Pump

Type

High-Pressure And Low-Pulse Double Plunger Tandem Advection Pump

Maximum Pressure

35MPa

Pressure Display Accuracy

≤0.1MPa

Flow Stability

(0.2-0.5)mL/min≤3%;
(0.5-1.0)mL/min≤2%;
>1.0mL/min≤2%;

Allowable Deviation of Flow

(0.2-0.5)mL/min , ±5%;
(0.5-1.0)mL/min, ±3%;
>1.0mL/min, ±2%;

Flow Range

0.001~9.999mL/min

Pressure Pulse

≤0.5%

Numerical-control and
Electromagnetic Sample
Injector


Maximum Pressure

35MPa

Contact Material of the Rotor

PEEK

Control Mode

By Stepper motor

Power Supply

24V (DC)

Digital and Temperature
-control Detection System


Type

Temperature--control and
bipolar conductivity detector

Detection Mode

Bipolar conductivity detection

Cell Volume

≤0.8μL

Detection Range

0~45000μS/cm

Detection Resolution

≤0.0020nS/cm

Output Voltage

6000~+6000 mV
(adjustable)

Baseline Noise

≤0.05% FS

Baseline Drift

≤3% FS/30min

Operating Temperature Range

Room temperature +5 ℃
~60 ℃

Controlling Temperature Accuracy

±0.01 ℃

Maximum Pressure

10.0MPa

Linear Range

≥103

Instrument Linearity

≥0.999

Quantitative Repeatability

≤1.0%

Qualitative Repeatability

≤1.0%

Minimum Detectable
Concentration

Cl-≤0.0005ug/mL;
Li+≤0.001 ug/mL;
BrO3-≤0.001 ug/mL;

Flow System


Plastic Flow Path

Made of PEEK materials

Six-way Valve

PEEK material, pressure
5000psi; Independent automatic collecting and flow function.

Power Supply

150W

External Size(L*W*H*)

350*470*510

Net Weight (KGS)

26

Gross Weight (KGS)

32

Previous: 
Next: 

Related Products

High Pressure Pump Maximum Pressure: 42MPa
Flow Range:0.001~9.999mL/min

 
0
0
Flow Rate Range: 0.001-9.999mL/min Increment: 0.001ml/min
Pressure Range: 《 42 Mpa for 316L pump head 
                            《 30 Mpa for PEEK pump head
0
0
Flow Range: 0.001mL/min-10.000mL/min; Setting Step Size: 0.001mL/min
Maximum Pressure: 42MPa
 
0
0
Maximum Pressure:   35MPa
Flow Range:  0.001~9.999mL/min
0
0

CONNECT WITH SCIENOVO

SCIENOVO
SOCIAL HUB

NEWSLETTER

Trusted Partner

Scienovo is a professional manufacture and supplier of scientific instruments in China, which is certified by ISO9001, ISO14001 and Intellectual Property Management System.

ABOUT SCIENOVO

PRODUCTS

CONTACT US

   No.10 Building, Pujiang Village , No.1188, Lianhang Road, Minhang District, Shanghai , China.

  info@scienovo.com

  +86-15901999577

  www.scienovo.com

Copyright © 2023 Shanghai Scienovo Scientific Instrument Co., Ltd All rights reserved.  Sitemap