SN-F96Pro
Scienovo
1 Years
OEM /ODM Service
Availability: | |
---|---|
Quantity: | |
Product Description |
Two modes could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic determination and quantity analysis could be done under fluorescence intensity mode.
365nm exciting wavelength Raman peak of water in 1 cm quartz fluorescence cuvette S/N≥150 ; High performance sensitivity simplifies the measurement of low detective sample.
10 stages gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N scanning and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre scanning feature, unknown sample’s spectrum information could be detected rapidly. Auto-omission of the influence of scattering peak and harmonic peaks, it ensures the best measurement parameters and locate the fluorescence emission peak.
Support off-line mode and on-line mode. Under off-line mode, instrument’s computer system offers the fluorescence intensity measurement, concentration direct reading, auto 0 adjustment, auto background subtraction etc. Under on-line mode, we could use quality and quantity software to control data acquisition and analysis through USB2.0 interface.
High stable and long life 150W xenon lamp and power source ensure high stable testing and wide range of spectrum.
The normalized feature for fluorescence value could make different fluorescence’s result comparable.
Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning, graphic calculation and storage-access abilities。
Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder for different features, 200μl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories, jacket sample accessories and etc.
Applications
Fluorescence analysis is a highly sensitive and high selective sophisticated analytical method. This method can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence etc. This method can provide a wide lineal range of working curve. It has become an important analytical method in the region of trace analysis.
Specifications |
Model | SN-F96PRO |
Light source | Hamamatsu 150W Xenon lamp |
Exciting optical filters | Interference optical filter |
Emission monochromator | C-T diffraction grating |
Emission wavelength | 200~900nm |
Emission bandwidth | 10nm |
Sensitivity | S/N≥150(P-P) |
Linear | ≥0.995 |
Stability | better than 1.5%/10min |
Power | 220V±22V 50Hz±1Hz |
Response time | (0.1-4) s 6 stages adjustable |
Fluorescence display value | 0.00-600.00 |
Data transmission | USB 2.0 |
Product Description |
Two modes could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic determination and quantity analysis could be done under fluorescence intensity mode.
365nm exciting wavelength Raman peak of water in 1 cm quartz fluorescence cuvette S/N≥150 ; High performance sensitivity simplifies the measurement of low detective sample.
10 stages gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N scanning and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre scanning feature, unknown sample’s spectrum information could be detected rapidly. Auto-omission of the influence of scattering peak and harmonic peaks, it ensures the best measurement parameters and locate the fluorescence emission peak.
Support off-line mode and on-line mode. Under off-line mode, instrument’s computer system offers the fluorescence intensity measurement, concentration direct reading, auto 0 adjustment, auto background subtraction etc. Under on-line mode, we could use quality and quantity software to control data acquisition and analysis through USB2.0 interface.
High stable and long life 150W xenon lamp and power source ensure high stable testing and wide range of spectrum.
The normalized feature for fluorescence value could make different fluorescence’s result comparable.
Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning, graphic calculation and storage-access abilities。
Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder for different features, 200μl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories, jacket sample accessories and etc.
Applications
Fluorescence analysis is a highly sensitive and high selective sophisticated analytical method. This method can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence etc. This method can provide a wide lineal range of working curve. It has become an important analytical method in the region of trace analysis.
Specifications |
Model | SN-F96PRO |
Light source | Hamamatsu 150W Xenon lamp |
Exciting optical filters | Interference optical filter |
Emission monochromator | C-T diffraction grating |
Emission wavelength | 200~900nm |
Emission bandwidth | 10nm |
Sensitivity | S/N≥150(P-P) |
Linear | ≥0.995 |
Stability | better than 1.5%/10min |
Power | 220V±22V 50Hz±1Hz |
Response time | (0.1-4) s 6 stages adjustable |
Fluorescence display value | 0.00-600.00 |
Data transmission | USB 2.0 |
Scienovo is a professional manufacture and supplier of scientific instruments in China, which is certified by ISO9001, ISO14001 and Intellectual Property Management System.
No.10 Building, Pujiang Village , No.1188, Lianhang Road, Minhang District, Shanghai , China.
+86-15901999577