SN-GCMS9600A
Scienovo
150℃-350℃:
EI sensitivity: 1pgOFNS/N400:1;1.5-1050 amu, the software can fully set and detect:
long-life 13-stage discontinuous dynode electron multiplier:2132; Maximum scanning speed: 10000amu/s, adjustable throughout:
1 Years
OEM /ODM Service
Availability: | |
---|---|
Quantity: | |
Product Description |
Introduction
The product integrates the functions of instrument tuning, data processing, and data analysis to improve the operational performance of the instrument and make research work more efficient.
Features
The temperature and pressure control precision of gas chromatography has reached the international first-class level.
The wide temperature RF power supply can adapt to various laboratory environments and perform more stably.
High-precision all-metal quadrupole, ensuring good resolution,
Quadrupole mass analyzer with pre-quadrupole, more resistant to pollution,
Electron multiplier with high- energy dynode, guaranteeing excellent sensitivity.
The high-performance turbomolecular pump ensures the high vacuum environment of mass spectrometry.
The inert ion source has high ionization efficiency, and the dual filament design provides double the service time.
Autosampler, purge and trap, thermal desorption, and headspace sampler can be configured according to the state of the sample.
Application
Food safety: pesticide residues, flavors, fragrances, additives, packaging materials
Environmental monitoring: air, water quality, soil, solid waste
Industrial manufacturing: textiles, cosmetics, electrical and electronic products, plastic products, biomedicine
Petrochemical: refinery, chemical plant
Public security system: criminal investigation, explosives, drugs, physical evidence identification
Specification |
Product Name | Gas Chromatography Mass Spectrometry | |
Product Model | SN-GCMS9600A | |
Mass Spectrometry Section | Ion source | Sensitivity: EI sensitivity: 1pgOFNS/N400: 1; |
Ion source material: inert ceramic ion source, equipped with double filaments; 2113 ionization energy: 10-100ev. | ||
Interface temperature: adjustable from 100°C to 350°C, the accuracy is better than 0.1°C, the mass spectrometer controls the temperature automatically, and does not occupy the auxiliary heating area of the gas chromatograph. | ||
Ion source temperature: 150℃-350℃: | ||
Mass Analyzer | Mass analyzer: high-precision metal quadrupole with preset rod. | |
Quadrupole temperature: quality stability can be guaranteed without temperature control. | ||
★Mass range: 1.5-1050 amu, the software can fully set and detect: | ||
Mass axis stability: better than 0.10 amu/48 hrs; | ||
Scanning mode: full scan, selected ion monitoring, full scan and selected ion synchronous monitoring, alternate scanning: | ||
Detectors | detector: long-life 13-stage discontinuous dynode electron multiplier: 2132 maximum scanning speed: 10000amu/s, adjustable throughout: | |
★Dynamic range: 106: | ||
★Peak area reproducibility<2% RSD; | ||
Direct air system: mechanical pump pumping speed ≥ 4m3/h: equipped with high-performance turbomolecular pump, pumping speed 250L/s | ||
The maximum allowable column flow rate is 5ml/min, helium. | ||
Maintainable parts: detachable ion source, filament, lens, pre-quadrupole and detector. | ||
Gas Chromatography | Oven | Temperature range: 5°C~450°C above room temperature; |
Temperature stability; when the ambient temperature changes by 1°C, it is better than 001°C | ||
Program heating: 6 stages and 7 platforms: | ||
Heating rate: the maximum heating rate is 120°C/min; | ||
Rapid cooling time: less than 5 minutes from 350°C to 50°C; | ||
Split/splitless capillary column inlet; | The maximum operating temperature is 400°C; | |
Pressure setting range: 0~100 psi, control accuracy 001psi; | ||
★ The injection port has pulse pressure; | ||
★Flow control | Electronic pneumatic control with constant current, constant pressure, program flow, program boost and other modes: | |
It can be configured with 16 or 24 liquid autosamplers | ||
★Reproducibility of retention time <0.02%. | ||
Software | ★Mass spectrometer and gas chromatograph are fully integrated in Chinese; the synchronous scanning function can obtain scan and sim data at the same time for a sample injection test, Improve the analysis efficiency; the alternate scan function can alternately scan and sim to expand the analysis function. | |
★In the middle of the operation, the time interval can be set to turn off the filament and electron multiplier to protect the filament, and the electron multiplier can avoid the solvent or other easily saturated substances that peak at the middle time. | ||
★The software can automatically select the characteristic ions of the target compound and group them according to the data obtained from the full scan and save them in the analysis method without manual input: | ||
Automatic shutdown; | ||
Chromatographic flow monitoring: chromatographic gas cut-off, mass spectrometry ion source, transmission valence line automatic cooling protection, mass spectrometry stop running: | ||
Molecular pump speed and current real-time monitoring, abnormal prompt. | ||
★ Selected ion mode detection (SIM) unlimited number of groups, each group can choose up to 128 ions. | ||
Operating Environment | Ambient temperature: 18-35℃, within 2 degrees of temperature fluctuation; | |
Relative humidity: <80%; | ||
Applicable power supply: 220V (+10%), 50Hz (2%) |
Product Description |
Introduction
The product integrates the functions of instrument tuning, data processing, and data analysis to improve the operational performance of the instrument and make research work more efficient.
Features
The temperature and pressure control precision of gas chromatography has reached the international first-class level.
The wide temperature RF power supply can adapt to various laboratory environments and perform more stably.
High-precision all-metal quadrupole, ensuring good resolution,
Quadrupole mass analyzer with pre-quadrupole, more resistant to pollution,
Electron multiplier with high- energy dynode, guaranteeing excellent sensitivity.
The high-performance turbomolecular pump ensures the high vacuum environment of mass spectrometry.
The inert ion source has high ionization efficiency, and the dual filament design provides double the service time.
Autosampler, purge and trap, thermal desorption, and headspace sampler can be configured according to the state of the sample.
Application
Food safety: pesticide residues, flavors, fragrances, additives, packaging materials
Environmental monitoring: air, water quality, soil, solid waste
Industrial manufacturing: textiles, cosmetics, electrical and electronic products, plastic products, biomedicine
Petrochemical: refinery, chemical plant
Public security system: criminal investigation, explosives, drugs, physical evidence identification
Specification |
Product Name | Gas Chromatography Mass Spectrometry | |
Product Model | SN-GCMS9600A | |
Mass Spectrometry Section | Ion source | Sensitivity: EI sensitivity: 1pgOFNS/N400: 1; |
Ion source material: inert ceramic ion source, equipped with double filaments; 2113 ionization energy: 10-100ev. | ||
Interface temperature: adjustable from 100°C to 350°C, the accuracy is better than 0.1°C, the mass spectrometer controls the temperature automatically, and does not occupy the auxiliary heating area of the gas chromatograph. | ||
Ion source temperature: 150℃-350℃: | ||
Mass Analyzer | Mass analyzer: high-precision metal quadrupole with preset rod. | |
Quadrupole temperature: quality stability can be guaranteed without temperature control. | ||
★Mass range: 1.5-1050 amu, the software can fully set and detect: | ||
Mass axis stability: better than 0.10 amu/48 hrs; | ||
Scanning mode: full scan, selected ion monitoring, full scan and selected ion synchronous monitoring, alternate scanning: | ||
Detectors | detector: long-life 13-stage discontinuous dynode electron multiplier: 2132 maximum scanning speed: 10000amu/s, adjustable throughout: | |
★Dynamic range: 106: | ||
★Peak area reproducibility<2% RSD; | ||
Direct air system: mechanical pump pumping speed ≥ 4m3/h: equipped with high-performance turbomolecular pump, pumping speed 250L/s | ||
The maximum allowable column flow rate is 5ml/min, helium. | ||
Maintainable parts: detachable ion source, filament, lens, pre-quadrupole and detector. | ||
Gas Chromatography | Oven | Temperature range: 5°C~450°C above room temperature; |
Temperature stability; when the ambient temperature changes by 1°C, it is better than 001°C | ||
Program heating: 6 stages and 7 platforms: | ||
Heating rate: the maximum heating rate is 120°C/min; | ||
Rapid cooling time: less than 5 minutes from 350°C to 50°C; | ||
Split/splitless capillary column inlet; | The maximum operating temperature is 400°C; | |
Pressure setting range: 0~100 psi, control accuracy 001psi; | ||
★ The injection port has pulse pressure; | ||
★Flow control | Electronic pneumatic control with constant current, constant pressure, program flow, program boost and other modes: | |
It can be configured with 16 or 24 liquid autosamplers | ||
★Reproducibility of retention time <0.02%. | ||
Software | ★Mass spectrometer and gas chromatograph are fully integrated in Chinese; the synchronous scanning function can obtain scan and sim data at the same time for a sample injection test, Improve the analysis efficiency; the alternate scan function can alternately scan and sim to expand the analysis function. | |
★In the middle of the operation, the time interval can be set to turn off the filament and electron multiplier to protect the filament, and the electron multiplier can avoid the solvent or other easily saturated substances that peak at the middle time. | ||
★The software can automatically select the characteristic ions of the target compound and group them according to the data obtained from the full scan and save them in the analysis method without manual input: | ||
Automatic shutdown; | ||
Chromatographic flow monitoring: chromatographic gas cut-off, mass spectrometry ion source, transmission valence line automatic cooling protection, mass spectrometry stop running: | ||
Molecular pump speed and current real-time monitoring, abnormal prompt. | ||
★ Selected ion mode detection (SIM) unlimited number of groups, each group can choose up to 128 ions. | ||
Operating Environment | Ambient temperature: 18-35℃, within 2 degrees of temperature fluctuation; | |
Relative humidity: <80%; | ||
Applicable power supply: 220V (+10%), 50Hz (2%) |
Scienovo is a professional manufacture and supplier of scientific instruments in China, which is certified by ISO9001, ISO14001 and Intellectual Property Management System.
No.10 Building, Pujiang Village , No.1188, Lianhang Road, Minhang District, Shanghai , China.
+86-15901999577